To optimize the reaction from Exp099 to make this Ugi product using Mettler Toledo's automated Minimapper. Forty eight reactions are run in parallel using four reactant (2.0M in methanol) in different solvents / concentration.
Procedure
Make up 2M methanol solutions (25mL each) of starting materials - Furfurylamine (4.418mL), Boc-glycine (8.759g) and tert-butyl isocyanide (5.655mL) and 2.077M Benzaldehyde solution (5.275mL / 25mL methanol)
The following are added in this order in a reaction tube equipped with a filtration frit
1) The additional solvent (200uL methanol)
2) The benzaldehyde solution
3) The Furfurylamine solution
4) The Boc-Glycine solution
5) The tert-butyl isocycanide solution
Parameters to modify:
concentration - 0.5M, 0.25M and 0.1M
reagent excess - 1.0 and 1.2 equivalents
solvent (for 0.25 and 0.1 conc only): ethanol, acetonitrile, THF
Limiting reagent conc : 0.2mmol
This is 48 experiments total and they are listed in this spreadsheet
2008-07-10
19:40 Started the run with minimapper.
20:50 Minimapperr completed the run..
21:00 Set the miniblock (red) on the shaker. 2008-07-11
17:00 Removed the miniblock from the shaker and vacuumed off excess solvent.
17:10 Set the miniblock on the minimapper and programmed it to deliver methanol (1mL) to each reaction tube.
17:30 Minimapper completed adding methanol to the reaction tubes.
17:32 Placed the miniblock on the shaker and started shaking at 400 rpm for 15 min.
17:50 Removed from the shaker and vacuumed off the solvent from the reaction tubes.
18:00 Set the miniblock on the minimapper and programmed it to deliver methanol (1mL) to each reaction tube for washing a second time.
18:25 Minimapper completed adding methanol to the reaction tubes.
18:30 Placed the miniblock on the shaker and started shaking at 400 rpm for 15 min.
18:45 Removed from the shaker and vacuumed off the solvent from the reaction tubes. The miniblock is let connected to the house vac for 30min.
19:15 The miniblock was disconnected from the house vac and placed in a desiccator connected to a high-vac.
Objective
To optimize the reaction from Exp099 to make this Ugi product using Mettler Toledo's automated Minimapper. Forty eight reactions are run in parallel using four reactant (2.0M in methanol) in different solvents / concentration.Procedure
Make up 2M methanol solutions (25mL each) of starting materials - Furfurylamine (4.418mL), Boc-glycine (8.759g) and tert-butyl isocyanide (5.655mL) and 2.077M Benzaldehyde solution (5.275mL / 25mL methanol)The following are added in this order in a reaction tube equipped with a filtration frit
1) The additional solvent (200uL methanol)
2) The benzaldehyde solution
3) The Furfurylamine solution
4) The Boc-Glycine solution
5) The tert-butyl isocycanide solution
Parameters to modify:
concentration - 0.5M, 0.25M and 0.1M
reagent excess - 1.0 and 1.2 equivalents
solvent (for 0.25 and 0.1 conc only): ethanol, acetonitrile, THF
Limiting reagent conc : 0.2mmol
This is 48 experiments total and they are listed in this spreadsheet
Map file ;
Results
Job file.Discussion
Conclusion
The results are not meaningful because the liquid handler was not properly programmed.Log
Log file1 ;2008-07-10
19:40 Started the run with minimapper.
20:50 Minimapperr completed the run..
21:00 Set the miniblock (red) on the shaker.
2008-07-11
17:00 Removed the miniblock from the shaker and vacuumed off excess solvent.
17:10 Set the miniblock on the minimapper and programmed it to deliver methanol (1mL) to each reaction tube.
17:30 Minimapper completed adding methanol to the reaction tubes.
17:32 Placed the miniblock on the shaker and started shaking at 400 rpm for 15 min.
17:50 Removed from the shaker and vacuumed off the solvent from the reaction tubes.
18:00 Set the miniblock on the minimapper and programmed it to deliver methanol (1mL) to each reaction tube for washing a second time.
18:25 Minimapper completed adding methanol to the reaction tubes.
18:30 Placed the miniblock on the shaker and started shaking at 400 rpm for 15 min.
18:45 Removed from the shaker and vacuumed off the solvent from the reaction tubes. The miniblock is let connected to the house vac for 30min.
19:15 The miniblock was disconnected from the house vac and placed in a desiccator connected to a high-vac.
Tags